Pressure senders
| Types: | |
1. Without warn. contact common ground |
|
| Application | |
The
instrument is suitable for measuring the pressure of the hidraulic,
or |
|
| Description | |
It is a membrane-system resistance-varying device built on a metal trunk placed in a deep-drawn metal case. At a determined pressure value, the slider of the varying resistance closes the current circuit of the signalling lamp by means of a contact pair. Some senders are not earthed, the earth is supplied by a separete connection. |
|
| Technical data | |
| Measuring range: | 0 - 300 kPa |
| 0 - 500 kPa | |
| 0 - 600 kPa | |
| 0 - 1000 kPa | |
| 0 -1200 kPa | |
| 0 - 1600 kPa | |
| 0 - 2500 kPa | |
| Switching value: | 40 600 kPa |
| Pressing tight: | 3000 kPa, max. 2 sec. |
| Permissible max. load: | 5 W, non inductive |
| Voltage: | 6 24 V |
| Tolerance in the linear section of the characteristic curve: | ±3% |
| Tolerance of the switching value: | between 40 200 kPa: ±15 kPa |
| between 200 350 kPa: ±20 kPa | |
| between 350 600 kPa: ±30 kPa | |
| Vibration proofness: | +10
dB on frequency range 25 -1000 Hz ( 0dB = g = 9.81 m/s2 ) |
| Protection: | dust and waterproof: IP 65 |
| electrical connection: IP 00 | |
| Temperature limits: | Operiting
temperature: -25°C ... +90°C |
| Storage
temperature: -40°C .. +85°C |
|
| Mass: | 0.15 kg |